Example 1
- Total rise: 2.8 m
- Number of steps: 16
Step height: 17.50 cm
What riser height is 2.8 m and 16 steps? 2.8÷16 = 17.50 cm.
Enter total rise and the number of risers. The calculator divides height by the count and shows centimeters. A 2.8 m storey and 16 risers is 17.50 cm. At 3.0 m and 17 steps you get 17.65 cm.
Total rise (m), Number of steps and Tread depth (cm). The result shows up here.
Riser height is a key comfort parameter for the flight. Related: 3-4-5 proportion, slope percent.
The stair calculator finds one riser height. The formula is h = H ÷ n, where H is total rise and n is the riser count. Optionally it shows Blondel 2h + s.
A 2.8 m storey and 16 risers is 17.50 cm. At 3.0 m and 17 steps the result is 17.65 cm. A lower 2.65 m ceiling and 15 steps is 17.67 cm. On the same 2.8 m: 15 risers give 18.67 cm, and 17 give 16.47 cm.
Enter total rise in the header unit, for example 2.8, and the riser count. Tread depth in centimeters is optional. A comma in 2.8 works the same as a period.
A square landing is the 3-4-5 proportion page. Driveway slope is a percent, not a riser. Concrete for treads lives on the concrete-volume page.
A tall riser wears you out on daily trips; a short one lengthens the flight. A common comfort band is about 15–20 cm. With a 29 cm going and 17.50 cm, Blondel is 64 cm.
Enter 2.8 and 16, click Calculate — you should get 17.50 cm. Then 3.0 and 17: 17.65 cm.
h = H ÷ n
Blondel (optional): 2h + s
H is total storey rise, n the riser count, h one riser height, s the tread going. 2.8 m ÷ 16 = 0.175 m = 17.50 cm. With a 29 cm going: 2 × 17.50 + 29 = 64 cm.
2.8 m and 16 risers is 17.50 cm. 3.0 m and 17 steps is 17.65 cm. A comfort band is usually 15–20 cm. Blondel 2h+s at 17.50 cm and 29 cm is 64 cm.
Step height: 17.50 cm
What riser height is 2.8 m and 16 steps? 2.8÷16 = 17.50 cm.
Step height: 17.65 cm
3.0 m and 17 risers → 17.65 cm. Still inside the 15–20 cm band.
Step height: 17.67 cm
2.65 m and 15 risers → 17.67 cm. Lower ceiling, similar step height.
Step height: 18.67 cm
2.8 ÷ 15 ≈ 0.1867 m → 18.67 cm. Higher than 16 risers on the same storey.
Step height: 16.47 cm
2.8 ÷ 17 ≈ 0.1647 m → 16.47 cm. A lower riser and a longer run at the same height.
17.50 cm · Blondel 64 cm
2 × 17.50 + 29 = 64. A common Blondel band is about 60–65 cm.
Divide total rise by the number of risers. 2.8 m and 16 steps → 2.8÷16 = 0.175 m = 17.50 cm. A common comfort band is about 15–20 cm.
17.50 cm. At 3.0 m and 17 risers the result is 17.65 cm. Both sit in the roughly 15–20 cm comfort band.
No. This page reports one riser height. Stringer cut lists, L-shaped runs, and landings are outside this tool.
No. It is a quick riser-height estimate plus an optional Blondel 2h+s comfort check. Local codes and the designer set the final sizes.
Yes. Enter total rise and the riser count (and optional tread depth) and you see centimeters per step at once. No account required.
The calculator divides total rise by the number of risers. A 2.8 m storey and 16 risers is 17.50 cm. At 3.0 m and 17 steps the result is 17.65 cm.
Usually about 15–20 cm. On the same 2.8 m: 15 risers give 18.67 cm, and 17 risers give 16.47 cm. The project and local codes decide the final limit.
It adds two riser heights and the tread going. At 17.50 cm and a 29 cm going the check is 64 cm, inside the usual 60–65 cm band. It is a comfort check, not a building code.
No. Height comes from total rise and the riser count. Depth only shows Blondel. An empty field leaves 17.50 cm at 2.8 m and 16 risers unchanged.
The header unit, usually meters (or feet in US units). 2.8 means a storey in meters. Entering 280 would be read as 280 m.
No. The calculator shows a quotient of two fields. Flight width, a handrail, landings, and the code stay outside this tool.
Increase the riser count if the layout allows. On 2.8 m, moving from 15 to 16 risers lowers the height from 18.67 cm to 17.50 cm.
Here the result is one riser height. The 3-4-5 page checks a right angle, for example on a landing. Driveway slope is a separate percent tool.
Yes. A comma and a period are the same rise. At 16 risers the result stays 17.50 cm.
Yes, as a quick riser-height estimate. Outdoors you also weigh material, freeze, and slip — outside this calculator.
Riser height is H ÷ n. Blondel 2h+s is a classic comfort check for a flight. Length units below from NIST.